fmri_processing_spm12r.Rmdspm12r functions
Requires MATLAB (installs SPM to R library)
spm12_slice_timing - slices are not taken
instantaneouslyspm12_realign - people movespm12_coregister - structural imaging is higher
resolutionspm12_segment - where’s the gray matter?spm12_normalize - brains look better in MNIspm12_smooth - turn that noise downWe will use the subject 113 from the Kirby21 data set to illustrate some basic operations of functional magnetic resonance imaging (fMRI). We will load in the T1 anatomical image and the fMRI from the respective packages.
library(kirby21.t1)
library(kirby21.fmri)
install_dir = tempdir()
outdir = tempfile()
dir.create(outdir)
stopifnot(download_fmri_data(outdir = outdir))
stopifnot(download_t1_data(outdir = outdir))
functional = get_fmri_filenames(ids = 113, visit = 1, outdir = outdir)
anatomical = get_t1_filenames(ids = 113, visit = 1, outdir = outdir)
files = c(anatomical = anatomical,
functional = functional)
filesWe know the repetition time (TR) is 2 seconds for this data. It may be encoded in the NIfTI file itself or come from a parameter file from the scanner. We will drop the first 20 seconds to allow for signal stabilization.
library(neurobase)
tr = 2 # seconds
DROP = 10 # 20 seconds for stabilization
fmri = readnii(files["functional"])
times = (DROP + 1):ntim(fmri)
run_fmri = copyNIfTIHeader(fmri, fmri[,,,times], drop = TRUE)Now run_fmri contains a nifti object with
the first 10 volumes dropped. We will pass this into the subsequent
functions.
As SPM requires MATLAB and calls all the functions through the
matlabr package, we will have checks in this
vignette/workflow that the user has MATLAB. The
have_matlab() function returns a logical that is
TRUE when matlabr can find MATLAB to run the
subsequent commands.
library(matlabr)
have_matlab()## [1] FALSE
If this is not TRUE, almost none of the functionality
below will run because it would simply result in errors.
We will show how to do spatial realignment, slice-timing correction, spatial normalization to the MNI template (2 different ways), and spatial smoothing. Overall, there are many different ways to order these operations, with different options, so this represents just one way to organize a preprocessing pipeline.
Realignment is referring to in this case as within-subject registration of the 4D fMRI data.
library(spm12r)
####################################
# Realignment
####################################
realign_batch = build_spm12_realign(
filename = run_fmri,
register_to = "mean",
reslice = "mean"
)
print(names(realign_batch))
print(names(unlist(realign_batch$spm)))
if (have_matlab()) {
realigned = spm12_realign(
filename = run_fmri,
register_to = "mean",
reslice = "mean",
clean = FALSE,
install_dir = install_dir
)
print(names(realigned))
}Overall the spm12_realign does the realignment. There is
some discussion of performing realignment before
slice-timing correction because estimation of motion parameters may be
skewed after slice-timing correction. We see that the output
realigned has the output 4D fMRI data
(outfiles), the realignment parameters (rp),
voxel-wise mean after realignment (mean), and the matrix of
transformations for the 4D series (mat).
Here we can read in the rp file to show the estimated
parameters. These can be used as regressors in motion correction for
further analyses.
####################################
# Read in Motion data
####################################
if (have_matlab()) {
rpfile = realigned[['rp']]
rp = read.table(file = rpfile, header = FALSE)
colnames(rp) = c("x", "y", "z",
"roll", "pitch", "yaw")
rp = as.matrix(rp)
print(head(rp))
print(dim(rp))
}A slice-timing correction does interpolation since each slice was not
actually taken at the same time point, but a shifted time point over the
course of an entire TR. The correction requires you to input the
reference slice (in this case the median, ref_slice), the
repetition time (tr), time between the first and the last
slice within one scan (ta), and the order the slices were
acquired. In our case, it was done in an ascending, contiguous order, so
we created the slice order as such. If you used descending or
interleaved acquisition, then this must be changed accordingly.
####################################
# Slice Timing Correction
####################################
nslices = oro.nifti::nsli(run_fmri)
slice_order = 1:nslices
ref_slice = slice_order[median(seq(nslices))]
ta = tr - tr/nslices
n_time_points = ntim(run_fmri)
# using run_fmri because if you do not have
# matlab, then realigned not available
st_batch = build_spm12_slice_timing(
filename = run_fmri,
time_points = seq(n_time_points),
nslices = nslices,
tr = tr,
ref_slice = ref_slice,
prefix = "a")
print(names(st_batch))
print(names(unlist(st_batch$spm)))
if (have_matlab()) {
st_results = spm12_slice_timing(
filename = realigned[['outfiles']],
time_points = seq(n_time_points),
nslices = nslices,
tr = tr,
slice_order = slice_order,
ta = ta,
ref_slice = ref_slice,
prefix = "a",
clean = FALSE,
retimg = FALSE,
install_dir = install_dir
)
aimg = st_results$outfile
print(aimg)
mean_img = realigned[["mean"]]
mean_nifti = readnii(mean_img)
}We see the output aimg has the filename of the
slice-timing corrected 4D image. We also read in the mean image into a
nifti object (mean_nifti).
if (!have_matlab()) {
run_fmri = filename_check(run_fmri)
}For the subsequent image normalization steps, SPM assumes the data is
aligned along the anterior commissure (AC) posterior commissure (PC)
line (AC-PC). The acpc_reorient function (based on
nii_setOrigin from Dr. Chris Rorden) will do this. The
syntax is that the first file (mean_img) is used to
estimate the line/plane and the subsequent files are reoriented using
this estimation (aimg). These are changes to the header of
the image and the image with the new header is written to the same file
as the input file.
if (have_matlab()) {
acpc_reorient(
infiles = c(mean_img, aimg),
modality = "T1",
install_dir = install_dir
)
}Here, we will spatially normalize the fMRI to the MNI template using
spm12_normalize. Here we specify a standard bounding box
for a 2mm MNI template. We are taking the mean image and directly
registering it to the MNI template (T1-weighted), and applying that
transform to the other.files, in this case the mean image
and the 4D fMRI image.
if (have_matlab()) {
bbox = matrix(
c(-90, -126, -72,
90, 90, 108),
nrow = 2, byrow = TRUE)
print(bbox)
direct_norm = spm12_normalize(
filename = mean_img,
other.files = c(mean_img, aimg),
bounding_box = bbox,
clean = FALSE,
install_dir = install_dir
)
print(names(direct_norm))
dnorm_files = direct_norm$outfiles
dnorm_mean_img = readnii(dnorm_files[1])
}We see the output direct_norm is a list with the output
files (outfiles). The order of these files is the same as
the order of those put in. In this case, the first file of
outfiles is the normalized mean image and second is the
normalized 4D image. Here we read in the spatially normalized mean image
to compare to the template later.
Indirect normalization refers to spatially normalizing the co-registered anatomical T1-weighted image to the MNI template. This transformation is applied to the mean image and 4D fMRI image. This is also referred to as Unified Segmentation.
Here we will perform the registration of the T1-weighted anatomical image into the space of the mean fMRI image after realignment. This is referred to as “co-registration” as it is within-subject registration, but across modalities (where we referred to within-subject, within-modality as realignment).
Here, we also reorient the anatomical image the AC-PC line. We then
perform the coregistration using spm12_coregister, where
the fixed image is the mean image and the moving image is the
anatomical.
if (have_matlab()) {
anatomical = files["anatomical"]
anat_img = checknii(anatomical)
print(anat_img)
acpc_reorient(
infiles = anat_img,
modality = "T1",
install_dir = install_dir
)
coreg = spm12_coregister(
fixed = mean_img,
moving = anat_img,
prefix = "r",
install_dir = install_dir
)
coreg_anat = coreg$outfile
coreg_img = readnii(coreg_anat)
double_ortho(coreg_img, mean_nifti)
}We see the anatomical image has been transformed and resliced into the mean fMRI image space (and thus has the resolution of that image).
Here we perform the segmentation of the co-registered anatomical image from above. This will segment the image into 6 different regions, where the regions are gray matter, white matter, cerebrospinal fluid (CSF), bone, soft tissue, and the background. You should inspect these visually before using them to ensure quality and no reordering due to artifacts.
if (have_matlab()) {
seg_res = spm12_segment(
filename = coreg_anat,
set_origin = FALSE,
retimg = FALSE,
clean = FALSE,
install_dir = install_dir
)
print(names(seg_res))
}In order to segment the image, SPM spatially normalizes the image to
the MNI template, however. This transformation will be the one we use to
transform the fMRI data to MNI space. We see in seg_reg a
deformation file, which is the transformation. We also see
the output segmentation files of the probability of each class, in
native space. We only tend to care about the first 3 categories.
If you would like to convert these class probabilities to a “hard”
segmentation, you must read the data in and use
spm_probs_to_seg for that. In
spm_probs_to_seg, each voxel is assigned the class with the
maximum probability, with options on how to choose ties (first is
default). We can then remove the labels for bone, soft tissue, and
background (> 3).
alpha = function(col, alpha = 1) {
cols = t(col2rgb(col, alpha = FALSE)/255)
rgb(cols, alpha = alpha)
}
if (have_matlab()) {
seg_files = check_nifti(seg_res$outfiles)
hard_seg = spm_probs_to_seg(seg_files)
hard_seg[ hard_seg > 3] = 0
ortho2(coreg_img, hard_seg,
col.y = alpha(c("red", "green", "blue"), 0.5))
}Now that we have estimated the transformation from the T1 image, we
can take that deformation and apply it to the fMRI data using
spm12_normalize_write. Again, we are registering to the MNI
template and will use a standard bounding box. We pass the anatomical,
mean fMRI, and 4D fMRI data in to be transformed.
bbox = matrix(
c(-90, -126, -72,
90, 90, 108),
nrow = 2, byrow = TRUE)
if (have_matlab()) {
norm = spm12_normalize_write(
deformation = seg_res$deformation,
other.files = c(coreg_anat, mean_img, aimg),
bounding_box = bbox,
retimg = FALSE,
install_dir = install_dir
)
print(names(norm))
norm_data = norm$outfiles
names(norm_data) = c("anat", "mean", "fmri")
norm_mean_img = readnii(norm_data["mean"])
norm_anat_img = readnii(norm_data["anat"])
}Now we have the indirect spatially normalized data in MNI template space
Here we will use the MNI 152 template to view results (the one we registered to). We create some crude masks to see how the overall brain overlaps with the template to make some comparisons.
if (have_matlab()) {
template_path = file.path(spm_dir(),
"canonical", "avg152T1.nii")
template = readnii(template_path)
dnorm_mask = dnorm_mean_img > quantile(
dnorm_mean_img[dnorm_mean_img > 0],
probs = 0.6)
norm_mask = norm_mean_img > quantile(
norm_mean_img[norm_mean_img > 0],
probs = 0.6)
double_ortho(template, norm_anat_img)
double_ortho(template, norm_mean_img)
double_ortho(norm_mean_img, norm_anat_img)
ortho2(template, norm_mask, col.y = alpha("red", 0.5))
double_ortho(template, dnorm_mean_img)
ortho2(template, dnorm_mask, col.y = alpha("red", 0.5))
double_ortho(norm_mean_img, dnorm_mean_img)
}Here we will perform spatial smoothing of the 4D fMRI data in template space. We can set the full-width half max (FWHM) for the Gaussian smoother. The relationship between the FWHM and the Gaussian standard deviation is:
where ` is the natural log.
if (have_matlab()) {
smoothed = spm12_smooth(
filename = norm_data["fmri"],
fwhm = 8,
prefix = "s",
retimg = FALSE,
install_dir = install_dir
)
smoothed_data = smoothed$outfiles
}In many applications, this is the data you will use for post-processing and analysis. Motion correction has usually been applied above, but some motion correct this data as well.
if (have_matlab()) {
smoothed_mean = spm12_smooth(
filename = norm_data["mean"],
prefix = "s",
retimg = FALSE,
install_dir = install_dir
)
smoothed_mean_data = smoothed_mean$outfiles
}Here we can smooth the mean image in MNI space. We could have also calculated a new mean image and smoothed that. Or we could have calculated a mean of the smoothed 4D data. They all may be slightly different.
if (have_matlab()) {
smooth_mean_img = readnii(smoothed_mean_data)
ortho2(smooth_mean_img)
}