estimateIRsolid.RdThe Inversion Recovery MRI signal in non-fluid voxel follows is modeled as a mixture of a fluid and a solid compartment.
Object of class "IRfluid" as generated by function estimateIRfluid.
Internal scale factor for Echo Times. This influences parameter scales in numerical calculations.
Internal scale factor for MR signals. This influences parameter scales in numerical calculations.
Logical. Provide some runtime diagnostics.
Lower bounds for parameter values.
Upper bounds for parameter values.
The Inversion Recovery MRI signal in non-fluid voxel follows is modeled as a mixture of a fluid and a solid compartment. The function calculates estimates of the maximum signal and recovery rate for the solid compartment and a mixture coefficient (proportion of fluid) for all voxel with segment%in%2:3using results from function estimateIRfluid.
List of class IRmixed with components
4D array containing the IRMRI data, first dimension refers to inversion times
vector of inversion times
segmentation codes, 1 for CSF, 2 for GM, 3 for WM, 0 for out of brain
noise standard deviation, if not specified estimated fron CSF areas in image with largest inversion time
effective number of coils
Array of fluid proportions
Array of maximal signals
Array of relaxation rates
Global estimate of maximal fluid signal
Global estimate of fluid relaxation rate
Covariance matrix of estimates fx, Sx and Rx.
Array of provided or estimated noise standard deviations
Array of convergence indicators
Residual standard deviations
"NLS" for nonlinear regression or "QL" for quasi likelihood.
Method used for variance estimation
The arrays contain entries for all voxel with segments%in%1:3.
J. Polzehl and K. Tabelow (2023), Magnetic Resonance Brain Imaging: Modeling and Data Analysis Using R, 2nd Edition, Chapter 7, Springer, Use R! Series. <doi:10.1007/978-3-031-38949-8_7>.
J. Polzehl and K. Tabelow (2023), Magnetic Resonance Brain Imaging - Modeling and Data Analysis Using R: Code and Data. <doi:10.20347/WIAS.DATA.6>.
# \donttest{
## runs about 7 seconds
dataDir0 <- system.file("extdataIR", package = "qMRI")
dataDir <- tempdir()
library(oro.nifti)
library(qMRI)
segm <- readNIfTI(file.path(dataDir0,"Brainweb_segm"))
Sf <- 900
Rf <- 0.000285
Sgm <- 400
Rgm <- 0.00075
fgm <- .15
Swm <- 370
Rwm <- 0.0011
fwm <- .05
InvTimes0 <- c(100, 200, 400, 600, 800, 1200, 1600, 2000, 2500, 3000,
3500, 4000, 4500, 5000, 6000, 15000)
nTimes <- length(InvTimes0)
sigma <- 40
## generate IR signal
IRdata <- generateIRData(segm, c(Sf,Rf), c(fgm,Rgm,Sgm), c(fwm,Rwm,Swm), InvTimes0, sigma)
for(i in 1:9) writeNIfTI(as.nifti(IRdata[i,,,]),
file.path(dataDir,paste0("IR0",i)))
for(i in 10:nTimes) writeNIfTI(as.nifti(IRdata[i,,,]),
file.path(dataDir,paste0("IR",i)))
## generate IRdata object
t1Files <- list.files(dataDir,"*.nii.gz",full.names=TRUE)
segmFile <- file.path(dataDir0,"Brainweb_segm")
IRdata <- readIRData(t1Files, InvTimes0, segmFile, sigma=sigma,
L=1, segmCodes=c("CSF","GM","WM"))
## estimate fluid
setCores(2) # parallel mode using 2 threads
#> Total CPU cores available: 4 CPU cores in use: 2.
IRfluid <- estimateIRfluid(IRdata, method="NLR", verbose=FALSE)
cat("Estimated parameters Sf:", IRfluid$Sf,
" Rf:", IRfluid$Rf, "\n")
#> Estimated parameters Sf: 1133.09 Rf: 0.0005374018
## estimate solid
IRmix <- estimateIRsolid(IRfluid, verbose=FALSE)
# }